SKU: ATO-DCCON-R200 Category:

Description

ATO ADC200 reversing contactor is used to change the direction of rotation in alternating current motors, start them gently and to monitor their load. Widely used in auto electric winch, telecommunication equiment, engineering machinery and other electric control system.

Features

  • 200 amps rated load current of contact circuit.
  • 2NO and 2NC contact form.
  • 12V, 24V, 48V DC coil rated voltage for selection.
  • Main contact voltage drop at 100A, not above 100mV.
  • Mechanical life up to 300 thousand times.

Specifications

Basics Model ATO-ADC200
Body Size 127*73*120 mm
Weight 1760 g
Technical Parameters Coil Rated Voltage 12V/24V/48V
Rated Load Voltage 12~60V DC
Contact Circuit Rated Load Current 200 A
Contact Form 2NO and 2NC
Starting Current ≤4 A
Overload Current ≤7 le
Coil Power ≤11 W
Main Contact Voltage Drop at 100A Load ≤100 mV
The Allowed Range of Coil Voltage ±20%
Pull-In Time (N/O Contacts to Open) ≤30 ms
Drop-Out Time (N/O Contact to Close) ≤20 ms
Insulation Resistance ≥50 MΩ
Dielectric Withstanding Voltage 50Hz/60Hz 1500VAC/Min
Electric Life Continuous 20000 times
Mechanical Life 300 thousand times
Environment Environmental Proctection IP 50
Operating Temperature -25℃~55℃
Operating Humidity 5~95% RH

DC Reversing Contactor Circuit Diagram
Installation Diagram (Unit: mm)

Details

Tips: Differences between AC contactor and DC contactor

  1. Different iron core: The iron core of an AC contactor is laminated by the insulated silicon steel sheets, which is in a double E shape; The iron core of an DC contactor is made from a whole soft iron, which is in a U shape.
  2. Different arc-extinguishing system: The AC contactor mainly adopts a splitter arc-extinguishing while the DC contactor adopts a magnetic quenching device.
  3. Different turns: AC contactor has fewer turns that are connected with the AC while DC contactor has more turns that are connected with DC. On-off of AC contactor is controlled by AC while that of DC contactor is controlled by DC. Highest operation frequency of AC contactor is 600 times per hour, the cost is low; while that of DC contactor could be as high as 2000 times per hour, the cost is high.