15 hp VFD, Single Phase to Three Phase VFD

Original price was: £1,453.95.Current price is: £290.79.

🚚 Free delivery over £60!

⚡ Fast dispatch

🔒 Secure Payment

⭐ Reliable quality

💬 Helpful customer service

📦 Fast delivery available across the whole country

SKU: GK3000-2S0110G Category:

Description

15 hp (11 kW) variable frequency drive, converts single phase to three phase for AC motor speed control.

Specification:

Basics Model GK3000-2S0110G
Capacity 15 hp (11 kW)
Shipping weight 8 kg
Dimension 330*200*200 mm
I/O Feature Rated current 45 A
Input voltage 1 phase 220~240V AC
Input frequency 50Hz/ 60Hz
Output voltage 3 phase AC 0~input voltage
Output frequency 0Hz~1000Hz
Over load capacity 150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control Feature Control mode V/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Communication RS485
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating IP 20
Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity 5%-95%, without condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Impingement and oscillation Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

Tips: How to set VFD acceleration and deceleration time?

RCF of VFD in starting and braking process is set by user. If the moment of inertia J and load of the motor increase or decelerate at a predetermined frequency, the acceleration torque may not be sufficient, thus resulting in the motor stall. Namely the motor speed is not in harmony with the output frequency of VFD, thus causing over-current or over-voltage. Therefore, the acceleration and deceleration time shall be set reasonably according to the moment of inertia and load of the motor, so that the RFC of VFD can be coordinated with the speed change rate of the motor.
The method to check whether this setting is reasonable is to select the acceleration and deceleration time according to experience. If over-current occurs during start-up, the acceleration time can be prolonged appropriately; In case the over-current occurs during braking process, the deceleration time shall be prolonged appropriately. In the other hand, the acceleration and deceleration time shall not be set too long, otherwise the production efficiency would be affected, particularly the frequent starting and braking.