Sale!

2 hp VFD, Single Phase 120V Input, 1ph/3ph 220V Output

Original price was: £315.38.Current price is: £63.07.

🚚 Free delivery over £60!

⚡ Fast dispatch

🔒 Secure Payment

⭐ Reliable quality

💬 Helpful customer service

📦 Fast delivery available across the whole country

SKU: GK3000-SP1S1-1d5 Category:

Description

2 hp (1.5 kW) VFD, single phase 110v/120v input to single phase 220v, 230v, 240v output, single phase to three phase, 7 amps.

Specification:

Basics Model EM15-SP1S1-1d5
Capacity 2 hp (1.5 kW)
Shipping weight 3 kg
Dimension (W x H x D) 120*205*166 mm
I/O Feature Rated current 7 A
Input voltage 1 phase 120V AC ±15% (Set FE-00=0)
Input frequency 50Hz/60Hz
Output voltage 1 phase or 3 phase 220V AC ±15%
Output frequency 0~320Hz (SFC)
Control Feature Control mode V/F control; vector control
Communication Offer RS485 communication interface, support MODBUS-RTU communication protocol
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating IP 20
Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity smaller than 95%RH, non-condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Vibration Less than 5.9 m/s2 (0.6 g)
Cooling forced air cooling
Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

Tips: Variable Frequency Drive vs Soft Starter

If you need to vary the speed of the driven load, then a VFD is definitely the choice. If you are looking to reduce the starting current and the starting torque of an induction motor, then a soft starter can be selected.
If energy savings (reduced speed) is the issue a VFD will almost always be the first choice, but again the driven load, (VT) and application require review and sizing considerations. If speed control is the consideration then a constant torque load will require a VFD. The motor basics we have had to live with, NEMA design A, B, C & D are there for a reason as one design doesn’t fit all applications. The controller is just another tool to use within it’s limitations to provide the desired result for an application.
Soft starter – considerably cheaper than VFDs, much more efficient, does not require harmonic mitigation, but draws 3 – 4 times start current and does not offer variable speed feature. Understanding the application and exactly what you are trying to achieve would be the most important factor.