Sale!

200 hp (150 kW) Soft starter, 300 A, 3ph 240v/400v/480v

Original price was: £1,379.53.Current price is: £275.90.

🚚 Free delivery over £60!

⚡ Fast dispatch

🔒 Secure Payment

⭐ Reliable quality

💬 Helpful customer service

📦 Fast delivery available across the whole country

SKU: GS-150 Category:

Description

200 hp soft starter, 150 kW three phase 240v, 400v, 480v, 690v AC motor starter.

Model GS2-150 (220v, 240v), GS3-150 (380v, 400v, 415v), GS4-150 (460v, 480v), GS6-150 (575v, 690v).
Capacity 200 hp (150 kw)
Current 300 amps at 380v/480v, 600 amps at 220v
Weight 21 kgs
Dimension 525*257*194 mm
Input Voltage Three-phase 220v, 420v, 480v, 690v AC
Frequency 50Hz/ 60Hz
Adaptive Motor Squirrel-cage three-phase asynchronous motor
Starting Times It is recommended not to exceed 20 times per hour.
485 Communication DB9 interface, male plug, ① is RS485+, ⑥ is RS485-
Control Mode
  1. Operation panel control.
  2. Operation panel + external control.
  3. External control.
  4. External control + COM control.
  5. Operation panel + external + COM control.
  6. Operation panel + COM control.
  7. COM control.
  8. No start or stop operation.
Start Mode
  1. Current-limiting to start.
  2. Voltage ramp to start.
  3. Torque control + current-limiting to start.
  4. Torque control + voltage ramp to start.
  5. Current ramp to start.
  6. Voltage current-limiting double closed-loop start.
Stop Mode
  1. Soft stop.
  2. Free stop.
Protective Function
  1. Open loop protection for external instantaneous stop terminals.
  2. Over-heat protection for soft starter.
  3. Protection for too long starting time.
  4. Input open phase protection.
  5. Output open phase protection.
  6. Unbalanced three-phase protection.
  7. Starting over current protection.
  8. Running overload protection.
  9. Under voltage protection for power voltage.
  10. Overvoltage protection for power voltage.
  11. Protection for fault parameter setting of the soft starter.
  12. Load short circuit protection.
  13. Auto restart or incorrect wiring protection.
  14. Incorrect wiring protection of external control stop terminals.
Ambient Place to be used Indoor location with good ventilation free from corrosive gas and conductive dust.
Altitude Below 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
Temperature -30 +55 oC
Humidity 90%RH without dew condensation.
Vibration <0.5G
Structure Enclosure IP 20
Cooling Natural wind cooling.

Details

Tips: Soft starter features

  1. Starting mode: According to the features of the load, selecting the different starting modes and parameter settings can make the motor to realize the starting effect in the maximum degree. Three starting modes: Voltage ramp starting – be able to get the maximum output torque, current-limiting starting – be able to effectively limit the starting current and inching – be able achieve the commissioning debugging function.
  2. High-tech performance: The use of high-performance microprocessors and powerful software support function simplifies the control circuit, there is no need of adjusting the circuit parameters, the consistent, accurate and fast execution speed and high-intensity anti-jamming function can be obtained.
  3. High reliability: All electrical apparatus elements of the soft starters of the motors are rigorously screened, the main control board must go through 72 hours of high temperature cycle test and vibration test, thus ensuring the high reliability of the outgoing products.
  4. Optimized structure: A unique compact modular structure and the upper incoming line and the lower outgoing line are very convenient for integration and complete sets of the users.
  5. Keyboard settings function: Soft starter has a convenient and intuitive operation display keyboard, and can set and modify the starting and stopping, running, protection and other parameters according to different loads.

Reviews

There are no reviews yet.

Be the first to review “200 hp (150 kW) Soft starter, 300 A, 3ph 240v/400v/480v”

Your email address will not be published. Required fields are marked *