Sale!

BAPI BA/AQPF-D-B-X-X-XX-X BAPI-Stat “Quantum Prime” CO2 Sensor, 0 to 10V Dual Channel 0 to 2,000 ppm CO2 Output, 10K-2 Thermistor Temperature Sensor, No Humidity Output, No Display, No Setpoint, No Override

Original price was: £222.00.Current price is: £55.50.

🚚 Free delivery over £60!

⚡ Fast dispatch

🔒 Secure Payment

⭐ Reliable quality

💬 Helpful customer service

📦 Fast delivery available across the whole country

SKU: BA\AQPF-D-B-X-X-XX-X Category:

Description

BAPI BA/AQPF-D-B-X-X-XX-X : BAPI-Stat “Quantum Prime” CO2 Sensor, 0 to 10V Dual Channel 0 to 2,000 ppm CO2 Output, 10K-2 Thermistor Temperature Sensor, No Humidity Output, No Display, No Setpoint, No Override

The BAPI-Stat “Quantum Prime” is a room CO2 sensor designed for demand controlled ventilation and continuously occupied spaces. It uses dual-channel NDIR sensing and automatic barometric pressure compensation to help maintain accurate CO2 readings across changing weather and altitude.

Common Applications

  • Demand controlled ventilation (DCV) for offices, schools, and commercial spaces
  • Indoor air quality monitoring tied into BAS controllers and VAV systems
  • Continuously occupied areas where stable CO2 measurement is needed

Specifications

  • Power: 15 to 24 VAC, 15 to 40 VDC
  • CO2 Sensor: Dual Channel Non-Dispersive Infrared (NDIR)
  • CO2 Range: 0 to 2,000 ppm
  • CO2 Output: 0 to 10V
  • CO2 Accuracy: <±50 ppm + 3% of measured value (typical at 77°F and sea level)
  • Start-Up Time: < 2 minutes
  • Response Time: < 2 minutes for 90% step change typical (after start-up)
  • Operating Environment: 32 to 122°F (0 to 50°C), 0 to 95% RH non-condensing
  • Temperature: 10K-2 Thermistor Temperature Sensor
  • Humidity: No Humidity Output
  • Display: °F Display

Construction

Item Details
Housing ABS Plastic, UL94 V-0
Mounting Standard 2″ x 4″ junction box, European junction box, or drywall mount
Indication Three front LEDs indicate CO2 level (Good, Fair, Poor)

Datasheets

CO2 Room Sensor, BAPI-Stat “Quantum Prime”
BAPI-Stat “Quantum Prime” CO2 Room Sensor Instructions
Effects of Temperature and Barometric Pressure on CO2 Measurement
Calibration Methods for Single and Dual Beam CO2 Sensors

Reviews

There are no reviews yet.

Be the first to review “BAPI BA/AQPF-D-B-X-X-XX-X BAPI-Stat “Quantum Prime” CO2 Sensor, 0 to 10V Dual Channel 0 to 2,000 ppm CO2 Output, 10K-2 Thermistor Temperature Sensor, No Humidity Output, No Display, No Setpoint, No Override”

Your email address will not be published. Required fields are marked *