Fixed Carbon Dioxide (CO2) Gas Detector, 0 to 9999 ppm

Original price was: £757.85.Current price is: £151.57.

🚚 Free delivery over £60!

⚡ Fast dispatch

🔒 Secure Payment

⭐ Reliable quality

💬 Helpful customer service

📦 Fast delivery available across the whole country

SKU: GD300-CO2 Category:

Description

Carbon dioxide gas detector provided by ATO manufacturer, reasonable price. Detecting range 0-1000/2000/5000/9999 ppm optional, output signal 4-20mA & RS485 for remote control. CO2 gas detector has fixed design, has sound and light alarm, real time display, 24 hours online for carbon dioxide leak monitor.

Features

  • Carbon dioxide gas detector adopts high precision sensor for accurate gas leak detection.
  • Carbon dioxide gas detector is equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • The CO2 gas detector is compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • The carbon dioxide gas detector has self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • The CO2 gas detector can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

Model GD300-CO2
Detection Principle Infrared
Gas Carbon Dioxide (CO2)
Range (Optional) 0 to 1000ppm, 0 to 2000ppm, 0 to 5000ppm, 0 to 9999ppm, 0 to 2% VOL, 0 to 5% VOL, 0 to 10% VOL, 0 to 20% VOL, 0 to 25% VOL, 0 to 30% VOL, 0 to 50% VOL, 0 to 100% VOL
Resolution 1ppm (0-1000/2000/5000/9999ppm), 0.001% VOL (0-2% VOL, 0-5% VOL), 0.01% VOL (0-10% VOL, 0-20% VOL, 0-25% VOL, 0-30% VOL, 0-50% VOL), 0.1% VOL (0-100% VOL)
Calibration Kit Gas pressure regulator (calibration gas cylinder NOT included)
Accuracy ≤±3% F.S.
Response Time ≤10s
Repeatability ≤±1%
Recovery Time ≤10s
Linearity Error ≤±1%
Zero Shift ≤±1% (F.S./year)
Signal Output (Optional) 4-20mA ans RS485
Relay output: one group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional).
Alarms Sound, light
Display High light nixie tube display
Installation Wall-mounted, piping type, flow-type (according to the detected environment)
Connection Power connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time 24h
Explosion-proof Grade II 2G Ex ia IIC T4 Ga
Protection Grade IP65
Certification CE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage 12-36V DC
Case Material Die-casting aluminum housing
Operating Temperature -20℃~50℃
Operating Humidity 0~95%RH (non-condensing)
Dimension 206*179*90mm
Weight ≤1.6kg
Power Adapter Input 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional) Calibration kit – gas pressure regulator (calibration gas cylinder NOT included)

  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note: To measure confined spaces such as pipelines, please contact us and inform the detailed conditions of use.

Fixed Carbon Dioxide (CO2) Gas Detector Dimension (Unit: mm)

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas Type Measure Range Resolution
Ammonia (NH3) 0-50/100/200/500/1000/2000/5000ppm 0.01ppm/0.1ppm/1ppm
Benzene (C6H6) 0-1/10/50/100/200/1000/2000/5000/10000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2) 0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL 0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO) 0-10/20/50/100/500/1000/2000ppm 0.01ppm/0.1ppm/1ppm
Chlorine (Cl2) 0-5/10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2) 0-1/5/10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX) 0-100%LEL 1%LEL
Ethylene (C2H4) 0-10/20/50/100/500/1000/2000ppm 0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O) 0-10/20/50/100/500/1000ppm 0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC) 0-100%LEL 1%LEL
Hydrogen (H2) 0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL 0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL) 0-10/20/50/100/200ppm 0.01ppm/0.1ppm
Hydrogen Cyanide (HCN) 0-10/20/50/100ppm 0.01ppm/0.1ppm
Hydrogen Sulfide (H2S) 0-5/20/50/100/200ppm 0.001ppm/0.01ppm/0.1ppm
Methane (CH4) 0-50/100%VOL, 0-100%LEL 0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO) 0-1/5/10/20/50/100/250/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2) 0-99.99/0-100%VOL 0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2) 0-1/5/10/20/50/100/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX) 0-1/5/10/20/50/100/250/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2) 0-25/30/100%VOL 0.01%VOL/0.1%VOL
Ozone (O3) 0-1/5/10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3) 0-10/20/50/100/500/1000/2000/3000ppm 0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2) 0-1/5/10/20/50/100/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC) 0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Tips: Precautions for carbon dioxide gas detector calibration.

  1. The calibration personnel must be trained, understand the principle and performance of carbon dioxide gas detector, be proficient in operating skills, and hold a certificate.
  2. The adjustment personnel must strictly follow the operating procedures.
  3. CO2 gas detector must be measured and appraised and can be used only after it is qualified.
  4. Before calibrating the carbon dioxide gas detector, perform a visual inspection. Calibration can be started after confirming the appearance is intact.
  5. CO2 gas detector that needs to be calibrated should be warmed up for about 20 minutes. Zero the carbon dioxide gas detector in fresh air.
  6. After the zero adjustment is completed, pass a standard gas sample with a concentration of about 1.0% according to the flow specified in the manual. Calibrate the displayed value of the carbon dioxide gas detector. The indicated value is consistent with the standard gas value and can be used after it is stable.