Description

Digital freezer temperature controller can set interval time and print temperature record on paper.

Specification:

Model ATO-TCFD2
Weight 0.5kg
Dimension (Length*High*Depth) 250*110*190mm
Supply voltage AC 85V-260V/50-60Hz, or DC 24V
Working environment Temperature: -10~60℃, humidity: ≤90%RH
Sampling period 8 times/second; When set digital filter parameter FILt=0, response time≤0.5s
Accuracy ±0.5%F.S ±1 digit
Resolution ≤0.01℃
Input signal * I1. Temperature sensor: CU50 (-50.0~150.0℃), PT100 (-199.9~600.0℃), K (-50.0~1300℃), E (-50.0~700.0℃), J (-30.0~900.0℃)
I2. Analog signal: 4-20mA, 0-10mA, 0-5V, 1-5V
Control mode 1. On-off control; 2. PID control
Need manually switch to another control mode.
Output mode * O1: Relay output; O2: SSR output
Alarm mode A1 Default mode: 1 alarm output
Alarm Upper limit, lower limit, upper deviation, lower deviation, in the deviation section, outside the deviation section
Printer type * P1: Needle printer; P2: Thermal printer

Note: Packing includes 1*freezer temperature controller, 1*RTD Pt100, and 1*DC 24V power supply. If you need other selection in the table, please contact customer service.
Freezer temperature controller wiring diagram:

Tips: What are relay output and analog quantity output?
Relay output is a kind of on/off output, and outputs 0 and 1 through ON and OFF status. Although relay output can directly connect to PLC, it should be noted that the relay is mechanical with low speed. So it is not suitable to use at high speed signal. And relay output is ON/OFF output and is not suitable for continuously changing analog signal. In addition, the relay is only a switch. The voltage input can’t be used directly when it needs to pull up or pull down, and the pull up and drop-down resistance is required.Analog output refers to output of continuously changing state. For example, 4-20mA current signal and a 0-5V voltage signal are continuous signals. In the instrument, the 4-20mA output represents the corresponding value of setting range. For example, in a thermometer (0~600℃), when the temperature is 0℃, the analog output of the instrument is 4mA. When the temperature is 300℃, the analog output of the instrument is 12mA.

Reviews

There are no reviews yet.

Be the first to review “Freezer Temperature Controller, Dual Digital, Pt100”

Your email address will not be published. Required fields are marked *